site stats

Dataphysics dcat11 germany

WebDataPhysics Instruments GmbH placeRaiffeisenstraße 34, 70794 Filderstadt, Germany phone +49 711 77 05 56 0, print+49 711 77 05 56 99 mail_outline info@dataphysics … WebMar 10, 2024 · Webinar Video: Vibration Data Acquisition to MATLAB with the Data Physics QUATTRO API. Last Updated on March 10, 2024 by dpnew Vibration Data Acquisition to …

DCAT software - DataPhysics Instruments

Webbalance system (Dataphysics DCAT11, Germany). X-ray absorption fine structure (XAFS) measurement and data analysis: XAFS spectra at the Co K-edge and Fe K-edge were measured at the beamline 1W1B station of the Institute of High Energy Physics (Chinese Academy of Sciences, China). All samples were pelletized as disks of 13 mm diameter with earbuds silicone cushion https://bruelphoto.com

Role of surface wettability in photoelectrocatalytic oxygen …

WebFeb 15, 2024 · Additionally, the contact angle, degree of crystallinity, BET specific surface area, particle size and point of zero charge (PZC) of the tested MPs were determined by a dynamic contact angle meter (Dataphysics DCAT11, Germany), X-ray diffraction (XRD, D8 Advance, Germany), surface area and porosity analyzer (ASAP 2024, USA), ImageJ … WebA special plus is the newly equipped laboratory, where Veronique will be pleased to demonstrate our surface science analysis devices to you. Looks neat, indeed! Get in … WebAug 24, 2024 · The CA and SA were measured using a dynamic CA measuring device (Dataphysics Corporation, DCAT11, Germany) at ambient temperature. The CA was measured four times at different positions. Deionized water droplets (approximately 3 μL) were carefully dropped onto the sample surface using a syringe. The transmittance of the … css animations on scroll

DCAT 21 - asi-team.com

Category:Photoelectrochemical Synthesis of Ammonia on the

Tags:Dataphysics dcat11 germany

Dataphysics dcat11 germany

ChineseAcademyofSciences,Lanzhou730000,PRChina

WebNov 10, 2024 · A density of ρ c = 1148.55 kg / m 3 at a temperature of 20 °C was measured with the density determination set DIS 11 (DCAT11, dataphysics, Filderstadt, Germany). The disperse phase consisted of a middle-chain triglyceride (MCT) Miglyol 812 ® (IOI Oleo GmbH, Witten, Germany). WebDataPhysics Instruments GmbH • Rai˜ eisenstraße ˚˛ • ˝˙˝ˆ˛ Filderstadt, Germany phone +˛ˆ (˙)˝ˇˇ ˝˝˙˘˘ -˙ • fax +˛ˆ (˙)˝ˇˇ ˝˝˙˘˘ -ˆˆ [email protected] • www.dataphysics.de Your …

Dataphysics dcat11 germany

Did you know?

Webof the DataPhysics DCAT 11 are: •the dynamic adsorption and contactangle measurementon wettable powders according to the modified and the extended … WebA Wilhelmy plate is a thin, generally rectangular plate made of iridium–platinum with a few centimeters in length and height. The material is chosen for reasons of good wetting …

WebSep 23, 2016 · The adhesive forces of the lubricants on the AISI 52100 steel were measured using the high-sensitivity micro-electromechanical balance system (Dataphysics DCAT11, Germany) with the adhesive force mode as described in the Ref. . The procedures are as follows: Steel surface was placed on the testing table of the … WebJan 1, 2024 · Adhesive force of the sample was tested by a surface tension detector (Dataphysics DCAT11, Germany) in the process of “contact-release” with a 3 μL water droplet suspended on a hydrophobic metal ring, where the relative humidity of ambient environment was ~ 70%. High-speed high-resolution motion analysis microscope system …

WebSep 15, 2024 · The adhesive force was measured utilizing a high-sensitivity micro-electromechanical balance system (Dataphysics DCAT11, Germany) with the volume of 4.0 μL. The values reported above were the average of five measurements at different locations. 2.4. Fog-harvesting test of slippery AMNSS. WebBut often ready-made products are too large or too heavy for measuring systems designed for laboratory use like the DataPhysics Instruments OCA series. With the portable …

http://www.ifrj.upm.edu.my/21%20(01)%202414/46%20IFRJ%2024%20(01)%202414%20Pornpen%20114.pdf

WebJan 15, 2014 · The adhesive force was measured using a high-sensitivity micro-balance system (Dataphysics DCAT11, Germany). The liquid droplets of 5 μL suspended on a hydrophobic metal ring were approached and retracted from the sample surface at a constant speed of 0.01 mm/s at ambient environment. The droplet started to move away … css animations on scroll - slide in from leftWebMar 5, 2024 · The water static contact angles (CAs) and rolling angles (RAs) were determined using an optical angle-measuring system (DSA100, KRÜSS, Germany). Moreover, the adhesive force of the sample surfaces was measured by a high sensitivity micro-electromechanical balance system (Dataphysics DCAT11, Germany). css animations propertieshttp://www.pss.aus.net/index.php?option=com_content&view=article&id=58&Itemid=71 css animations ppthttp://www.asi-team.com/asi%20team/dataphysics/DataPhysics%20data/DCAT21.pdf earbuds size sound qualityWebFeb 15, 2024 · The interaction force between the gas bubbles and membrane surfaces were measured using a high-sensitivity microelectromechanical balance system (Dataphysics DCAT11, Germany), and the under-brine bubble contact angle was assessed by the captive bubble method (KRUSS DSA30). The volume of gas bubble was set to be 4 μL for each … earbuds sims 4 ccWebAt DataPhysics, we take the Plug and Play principle seriously. 1 Suspended liquid drop to be evaluated with the Pendant Drop method 2 Fiber bundle with liquid lamella to … css animation spin not workingWebDataPhysics Instruments GmbH · Raiffeisenstraße 34 · D-70794 Filderstadt phone ++49 (0)711 770556-0 · fax ++49 (0)711 770556-99 email [email protected] · internet … css animations react